| Pump installation must be placed with the impeller
18" (eighteen) inches below the water line. The pump
is not self priming.
The suction run can have 4 (four) 90 degree elbows without affecting the flow. The return line should be a straight run. For gunite ponds plumb the pump prior to pouring. Make sure the shaft/impeller is wired correctly to turn in counter clockwise movement. Inspect PVC pipe for truest round for easier connection. Use Slow-set Glue - #719 Extra Heavy Body Slow Set. Manufactured specifically for pipe 10 to 22 inches. This glue allows extra time for setting fittings. Never operate the pump without water being pumped through the unit. It has a water lubricated bearing in the shaft assembly. For easier connection with the PVC pipe, we recommend beveled ends at 7 degrees X 3/8 inch long with a sander. Do not cut bevel through to inside edge. Do not bevel the fittings. |
|
. |
![]() |
![]() |
![]() |